Series 5 Polyurethane
Heavy Duty Element
Object
A two stage air cleaner and oil treated multi-layer
polyurethane element was supplied for dust testing.
Method
Test Method - ISO 5011 Air Flow:- 23m3/min
Efficiency Measured Dust Type:- ISO Coarse PTI Batch
5306c
by Absolute Filter Method Dust Conc.:- 2g/m3
Final Limit:- Stopped at 1.9 kPa
The
intention was to perform a comparison dust test to a 5kPa
pressure drop limit. Due to the capacity of the element
being very high, it was decided that the test should be
stopped after 1.9 kPa was reached on this test.
Results
Air Cleaner after test |
Polyurethane Element after testing |
Test
No. |
Init.
PD
(kPa) |
DHC
(g) |
First
Stage
Efficiency (%) |
O/A
Effic.
(%) |
Series
5 polyurethane Element |
0.72 |
8432 |
61.6 |
99.47 |
Conclusions
At 1.9kPa final pressure drop, the Series 5 element had
dust capacity of 8432g, and an efficiency of 99.47% against
ISO coarse test dust using the ISO5011 test protocol.